Operating Noise Level of the S30P Evaporator
Evaporator Sound Test
Technician: Gordon Spelay
Test date: February 16, 1999
Location: AC Motor Electric, Penticton, BC
Weather conditions: Overcast and calm
Meter: No. 33-2055
| Distance from the evaporator in feet | Readings in db’s |
| 0 ft | 99db |
| 5 ft | 98db |
| 25ft | 93db |
| 50ft | 89db |
| 75ft | 85db |
| 100 ft | 75db |
| 200 ft | 65db |
NOTES
- Test site was flat and unobstructed.
- Test readings were also taken from behind surrounding buildings at a distance of approximately 150 feet. These reading ranged from 65 Db to 75 db.
- Normal speech pattern will register between 65-70 db’s.