Nature's Environmental Solution

Specifications

Operating Noise Level of the S30P Evaporator

Evaporator Sound Test

Technician: Gordon Spelay
Test date: February 16, 1999
Location: AC Motor Electric, Penticton, BC
Weather conditions: Overcast and calm
Meter: No. 33-2055

Distance from the evaporator in feet Readings in db’s
0 ft 99db
5 ft 98db
25ft 93db
50ft 89db
75ft 85db
100 ft 75db
200 ft 65db

NOTES

  1. Test site was flat and unobstructed.
  2. Test readings were also taken from behind surrounding buildings at a distance of approximately 150 feet. These reading ranged from 65 Db to 75 db.
  3. Normal speech pattern will register between 65-70 db’s.


If you have questions about our design, please contact sales at: 1 800 495 6145